Typo.
[breezed.git] / breezed.1
index 2f01520..750bc08 100644 (file)
--- a/breezed.1
+++ b/breezed.1
@@ -1,4 +1,4 @@
-.TH "BREEZED" "1"
+.TH "BREEZED" "1.4" "Mar 2010" "Francois Fleuret" "System Deamons"
 .SH "NAME"
 breezed - Fan control daemon
 .SH "SYNOPSIS"
@@ -6,38 +6,42 @@ breezed - Fan control daemon
 \fBbreezed\fP [\fBoptions\fP]
 .SH "DESCRIPTION"
 .PP
-\fBbreezed\fP Adjusts the fan speed according to the computer
-temperature. It should be started through the adequate script in
-/etc/rc?.d.
+\fBbreezed\fP is a daemon to adjust the fan speed according to the
+computer temperature. It should be started through the adequate
+systemd configuration or script in /etc/rc?.d.
 
-Every 5s, this daemon gathers all integer values from the thermal
-files, and keep the max as the overall computer temperature T. It then
-pick the highest temperature threshold lower than T and set the fan
-speed to the corresponding level. To avoid oscillations, T has to be
-two degrees below threshold to reduce the temperature. Also, the
-daemon waits for at least 30s after any change of the fan speed before
-reducing it. The fan speed is set by writing "level %d" into the
-specified fan file.
+Every 5s, \fBbreezed\fP gathers all integer values from the thermal
+files, and takes the max as the overall temperature T. It then
+computes the highest fan speed whose temperature threshold is lower
+than T. If that speed is above the current speed, the daemon changes
+the fan speed accordingly. Otherwise it computes the lowest fan speed
+whose temperature threshold is two degrees above T, and sets the fan
+speed one level below. This two degree gap avoids too many
+oscillations. Also, the daemon waits for at least 30s after any change
+of the fan speed before reducing it. The fan speed is set by writing
+"level <speed_name>" into the specified fan file. The speed name is
+the level itself if no alternative is provided with the temperature
+threshold.
 
-Options can not be specified twice, neither on the command line nor in
+Options cannot be specified twice, neither on the command line nor in
 the configuration file.
 
 .SH "OPTIONS"
-.IP "\fB-h | --help\fP         " 10
+.IP "\fB-h | --help\fP" 10
 display help and exits
-.IP "\fB-v | --version\fP " 10
+.IP "\fB-v | --version\fP" 10
 display the version number and exits
-.IP "\fB-d | --debug\fP " 10
+.IP "\fB-d | --debug\fP" 10
 run in verbose mode
-.IP "\fB-cf | --configuration-file <file>\fP " 10
+.IP "\fB-cf | --configuration-file <file>\fP" 10
 set the configuration file (default is /etc/breezed.conf)
-.IP "\fB-ncf | --no-configuration-file\fP " 10
+.IP "\fB-ncf | --no-configuration-file\fP" 10
 prevent the reading of a configuration file
-.IP "\fB-tf | --thermal-file <file1>[,file2]...\fP " 10
+.IP "\fB-tf | --thermal-file <file1>[,file2]...\fP" 10
 set the files to spool for temperatures.
-.IP "\fB-ff | --fan-file <file>\fP " 10
+.IP "\fB-ff | --fan-file <file>\fP" 10
 set the file to control the fan speed.
-.IP "\fB-tt | --temperature-thresholds <temp1>[,temp2]...\fP " 10
+.IP "\fB-tt | --temperature-thresholds <temp1>[:<speed_name_1>][,temp2[:speed_name_2]]...\fP" 10
 set the temperature thresholds.
 
 .SH "CONFIGURATION FILE"
@@ -50,18 +54,29 @@ at /etc/breezed.conf
 
 .SH "EXAMPLES"
 
-A typical way of starting breezed is
+If a configuration file exists, the standard way to start breezed is
+to run it without arguments.
 
-breezed --thermal-files /proc/acpi/thermal_zone/THM0/temperature,/proc/acpi/thermal_zone/THM1/temperature \
- --fan-file /proc/acpi/ibm/fan \
- --temperature-thresholds -1,52,54,56,58,60,62,64
+Starting it with all the arguments on the commande line can be done
+for instance with
+
+.P
+.nf
+.B breezed --no-configuration-file \e
+.B \ \ \ \ \ \ \ \ --thermal-files /proc/acpi/thermal_zone/THM0/temperature,/proc/acpi/thermal_zone/THM1/temperature \e
+.B \ \ \ \ \ \ \ \ --fan-file /proc/acpi/ibm/fan \e
+.B \ \ \ \ \ \ \ \ --temperature-thresholds 52,54,56,58,60,62,64,68:full-speed
 
 which specifies that when the temperature raises above 52C, the fan
 level should be 1, when the temperature raises above 54C it should be
-2, etc. The maximum speed level 7 should be chosen for temperature
-above 64C. Due to the two degrees gap between the thresholds to
-increase and thresholds to decrease the temperature, it will for
-instance remains at speed 1 until the temperature goes down to 50C.
+2, etc. The maximum speed level 8 should be chosen for temperatures
+above 68C, and its name is "full-speed" (since no other speed name is
+provided, the other ones are the default level names, hence their
+numerical value).
+
+Due to the two degrees gap between the thresholds to increase and the
+thresholds to decrease the temperature, it will for instance remains
+at speed 1 until the temperature goes down to 50C.
 
 Because it takes into account all the values found in the thermal
 files, you can use as well /proc/acpi/thermal_zone/THM?/temperature or
@@ -69,6 +84,6 @@ files, you can use as well /proc/acpi/thermal_zone/THM?/temperature or
 
 .SH "AUTHOR"
 .PP
-Written by Francois Fleuret <francois@fleurer.org>. Permission is
+Written by Francois Fleuret <francois@fleuret.org>. Permission is
 granted to copy, distribute and/or modify this document under the
 terms of the GNU GPL.