@@ -7,8 +7,8 @@ breezed - Fan control daemon
 .SH "DESCRIPTION"
 .PP
 \fBbreezed\fP is a daemon to adjust the fan speed according to the
-computer temperature. It should be started through the adequate script
-in /etc/rc?.d.
+computer temperature. It should be started through the adequate
+systemd configuration or script in /etc/rc?.d.
 
 Every 5s, \fBbreezed\fP gathers all integer values from the thermal
 files, and takes the max as the overall temperature T. It then
@@ -20,10 +20,10 @@ speed one level below. This two degree gap avoids too many
 oscillations. Also, the daemon waits for at least 30s after any change
 of the fan speed before reducing it. The fan speed is set by writing
 "level <speed_name>" into the specified fan file. The speed name is
-the leve itself if no alternative is provided with the temperature
+the level itself if no alternative is provided with the temperature
 threshold.
 
-Options can not be specified twice, neither on the command line nor in
+Options cannot be specified twice, neither on the command line nor in
 the configuration file.
 
 .SH "OPTIONS"
@@ -60,10 +60,12 @@ to run it without arguments.
 Starting it with all the arguments on the commande line can be done
 for instance with
 
-breezed --no-configuration-file \
- --thermal-files /proc/acpi/thermal_zone/THM0/temperature,/proc/acpi/thermal_zone/THM1/temperature \
- --fan-file /proc/acpi/ibm/fan \
- --temperature-thresholds 52,54,56,58,60,62,64,68:full-speed
+.P
+.nf
+.B breezed --no-configuration-file \e
+.B \ \ \ \ \ \ \ \ --thermal-files /proc/acpi/thermal_zone/THM0/temperature,/proc/acpi/thermal_zone/THM1/temperature \e
+.B \ \ \ \ \ \ \ \ --fan-file /proc/acpi/ibm/fan \e
+.B \ \ \ \ \ \ \ \ --temperature-thresholds 52,54,56,58,60,62,64,68:full-speed
 
 which specifies that when the temperature raises above 52C, the fan
 level should be 1, when the temperature raises above 54C it should be