\fBbreezed\fP [\fBoptions\fP]
.SH "DESCRIPTION"
.PP
-\fBbreezed\fP Adjusts the fan speed according to the computer
-temperature. It should be started through the adequate script in
-/etc/rc?.d.
+\fBbreezed\fP is a daemon to adjust the fan speed according to the
+computer temperature. It should be started through the adequate script
+in /etc/rc?.d.
-Every 5s, this daemon gathers all integer values from the thermal
-files, and keep the max as the overall computer temperature T. It then
-pick the highest temperature threshold lower than T and set the fan
-speed to the corresponding level. To avoid oscillations, T has to be
-two degrees below threshold to reduce the temperature. Also, the
-daemon waits for at least 30s after any change of the fan speed before
-reducing it. The fan speed is set by writing "level %d" into the
-specified fan file.
+Every 5s, \fBbreezed\fP gathers all integer values from the thermal
+files, and takes the max as the overall temperature T. It then
+computes the highest fan speed whose temperature threshold is lower
+than T. If that speed is above the current speed, the daemon changes
+the fan speed accordingly. Otherwise it computes the lowest fan speed
+whose temperature threshold is two degrees above T, and sets the fan
+speed one level below. This two degree gap avoids too many
+oscillations. Also, the daemon waits for at least 30s after any change
+of the fan speed before reducing it. The fan speed is set by writing
+"level <level>" into the specified fan file.
Options can not be specified twice, neither on the command line nor in
the configuration file.
.SH "OPTIONS"
-.IP "\fB-h | --help\fP " 10
+.IP "\fB-h | --help\fP" 10
display help and exits
-.IP "\fB-v | --version\fP " 10
+.IP "\fB-v | --version\fP" 10
display the version number and exits
-.IP "\fB-d | --debug\fP " 10
+.IP "\fB-d | --debug\fP" 10
run in verbose mode
-.IP "\fB-cf | --configuration-file <file>\fP " 10
+.IP "\fB-cf | --configuration-file <file>\fP" 10
set the configuration file (default is /etc/breezed.conf)
-.IP "\fB-ncf | --no-configuration-file\fP " 10
+.IP "\fB-ncf | --no-configuration-file\fP" 10
prevent the reading of a configuration file
-.IP "\fB-tf | --thermal-file <file1>[,file2]...\fP " 10
+.IP "\fB-tf | --thermal-file <file1>[,file2]...\fP" 10
set the files to spool for temperatures.
-.IP "\fB-ff | --fan-file <file>\fP " 10
+.IP "\fB-ff | --fan-file <file>\fP" 10
set the file to control the fan speed.
-.IP "\fB-tt | --temperature-thresholds <temp1>[,temp2]...\fP " 10
+.IP "\fB-tt | --temperature-thresholds <temp1>[,temp2]...\fP" 10
set the temperature thresholds.
.SH "CONFIGURATION FILE"
breezed --thermal-files /proc/acpi/thermal_zone/THM0/temperature,/proc/acpi/thermal_zone/THM1/temperature \
--fan-file /proc/acpi/ibm/fan \
- --temperature-thresholds -1,52,54,56,58,60,62,64
+ --temperature-thresholds 52,54,56,58,60,62,64
which specifies that when the temperature raises above 52C, the fan
level should be 1, when the temperature raises above 54C it should be